SPECIFICATIONS
|
Technology |
Lithium Iron Phosphate |
Nominal Voltage |
12.8 V |
Fully Charged Voltage (FC) |
14.6V |
Fully Discharged Voltage (FD) |
9.2V |
Capacity |
300Ah |
Recommended Discharge Current |
300A |
Battery Discharge Terminated Voltage |
9.2V |
Battery Charge Voltage |
14.2V |
Maximum Charge Current |
300A |
Discharge Cut-off Voltage |
8.4 V |
Recommended Charge Current |
20A – Battery pack at 0°C~5°C & 45°C ~ 55°C |
50A – Battery pack at 5°C~15°C |
100A – Battery pack at 15°C~45°C |
Standard Charge Method |
0.2C CC (constant current) charge to FC, then CV (constant voltage FC) charge till charge current decline to ≤ 0.05C |
Inner Resistance |
≤ 10 mΩ |
Certifications |
ETL, CE, UKCA, UN38.3, UL 2054 |
Operating Temperature |
Charge: -4°F (-20°C) to 131°F (55°C) |
Discharge: -4°F (-20°C) to 131°F (55°C) |
Storage Temperature |
1 month: > 113°F (45°C) to 131°F (55°C) – Max 80% |
3 months: > 77°F (25°C) to 113°F (45°C) – Max 80% RH |
6 months: > -4°F (-20°C) to 77°F (25°C) – Max 80% RH |
Humidity |
Operating: 5% to 90 % RH; Storage: 45% to 85% RH |
BMS Leakage Current |
35mA in on mode; < 20µA during off mode |